Static Compliance Calculator

Calculates static compliance from VT, Pplat, and PEEP.

Inputs

Color mode links each input to the matching equation term and solving arithmetic.

Equation and Work

Equation:
Solving steps:
Pplat − PEEP
cmH₂O
Cstat
mL/cmH₂O
Normal/reference: Static compliance 40–60 mL/cmH₂O. If the patient is intubated, use serial measurements to establish trend.

Clinical Significance

Static compliance estimates respiratory system compliance using plateau pressure and PEEP.

It emphasizes elastic load because plateau pressure is measured during no-flow conditions.

Valid measurement requires an inspiratory hold and minimal patient effort during the plateau pressure measurement.

References (APA 7th Edition)

  1. Attached equations reference supplied by the user for calculator equation confirmation.